top of page
Foto do escritor PAULO ROSSETTI

Próteses fixas em zircônia se sustentam bem em espaços interoclusais reduzidos

Atualizado: 10 de jun.




Zirconium Oxide three-Unit Fixed Partial Denture Frameworks Supported by Dental Implants in Acceptable and Reduced Interocclusal Space Possibilities: Pilot In vitro Fracture Strength and Fractographic Analyses



Sérgio Alexandre Gehrke

Wellington Cardoso Bonachela

Jéssica Monique Lopes Moreno

Paulo Henrique Orlato Rossetti

Guillermo Castro Cortellari

Berenice Alina Dedavid

José Luis Calvo-Guirado


Purpose: This study investigated the effect of fracture strength and fracture mode characteristics related to reduced interocclusal space on computer-aided design/computer-aided manufacturing (CAD/CAM). ZrO2 fixed partial denture (FPD) frameworks subjected to quasi-static loads.

Materials and methods: First, two dental implants (4 × 10 mm) were positioned simulating a three-unit FPD (second premolar and second molar abutments). The implants were distributed into two groups: control group (n = 10), positioned at the same level; and the test group (n = 10), where the interocclusal space corresponding to the second molar was reduced by 3 mm in relation to the second premolar to simulate a clinical situation. After FPD wax-up (25-mm long; connector height = 5 mm; connector width = 3 mm, proximal and lingual collar reinforcement), casting was made in a Co-Cr alloy to serve as a prototype. Upon scanning, screw-retained CAD/CAM ZrO2 FPDs were fabricated for each group. Then, FPDs were subjected to quasi-static axial loading until fracture in the mid-occlusal pontic area using a universal testing machine at the crosshead speed of 0.5 mm/min. Next, the samples were analyzed by scanning electronic microscopy (SEM) to describe the fracture characteristics.

Results: The mean fracture strength values for the control group (1,747.4 ± 122.3 N) and test group (1,817.7 ± 158.9 N) showed no significant difference (Student t test, P < .124). The SEM images of the fracture sites revealed two cleavage areas in the test group, providing representative sites with increased fracture energy storage in this group compared with the control group.

Conclusion: Within the limitations of this study, the results showed that reduced interocclusal space and reduced length did not decrease the fracture strength of the ZrO2 FPD frameworks.






Comentarios


bottom of page